Facet HP Series single-stage water coalescers, commonly referred to as repack or hay pack housings, are horizontal, cylindrically shaped housings designed to protect filtration systems from gross amounts of water and solid contaminants. Facet recommends using their wafer style repack coalescers since they allow the first two sections to be replaced when required. The third and successive sections require fewer changeouts since they may remain relatively free of solids.

Coalescing first starts as the product enters the vessel. Due to the substantially reduced velocity, free water will fall out by gravity. While the product progresses through the mass packed media, further coalescing occurs by impingement of water droplets on the media. At the same time, solids tend to fall out as the liquid enters the housing at a reduced velocity, but are further removed by filtration as the flow continues through the mass media.

All Facet HP Series single-stage water coalescer housings are built to ASME Code, Section VIII, with many standard and optional accessories available to facilitate individual installation requirements.

Facet HP Series single-stage coalescers use wafer repacks to remove gross amounts of water and solids from fuel. They are available in several standard sizes to accommodate flows from 10 to 2000 gpm (38 to 7570 lpm). They provide protection to filtration systems from gross amounts of water and solids that are commonly carried through inbound transport pipelines.

HP Series housings offer an option of using coalescer cartridges for more efficient solids separation and liquid-liquid water separation. Use of an adaptor kit permits returning to the use of repacks at any time.

HP Series housings have no internal moving parts and are designed for easy servicing, thereby reducing maintenance costs. Each housing is manufactured with quality workmanship and materials to give long-lasting and dependable service.




Unit of Measure: Imperial Metric Both

 Specifications   Standard Design Features   

Manufacturer

Facet International

Product Type

Coalescer Housings

Series

HP

Design Pressure at 250ºF

150 psi

Closure Seal

Buna-N

Exterior

Prime Coated

Inlet Connection Type

150# RF (ANSI) Flanged

Outlet Connection Type

150# RF (ANSI) Flanged

All Other Connection Type

3000# NPT Female Coupling

Housing Style

Style A

Flow Rate

View
510 gpm
1930
lpm
68.18
cfm

Housing Liquid Volume

610.5 gal
2310
lit

Shipping Weight

4000
1816
kg

Inlet Connection Size

6 in
152
mm

Outlet Connection Size

6 in
152
mm

Vent and Relief Connection Size

1 1/2 in
38
mm

Drain Connection Size

2 in
51
mm

Level Gauge Connection Size

3/4 in
19
mm

Level Control Connection Size

1 1/2 in
38
mm

A

36 in
914
mm

B

82 1/2 in
2095
mm

C

92 in
2337
mm

D

21 in
559
mm

E

98 in
2489
mm

F

28 in
711
mm

G

24 in
610
mm

H

12 in
305
mm

L

16 in
406
mm

Options

Internal epoxy coating
Steel stands


Contact Becker & Associates